sala eléctrica de celdas

17:50 Aug 15, 2020
Spanish to English translations [PRO]
Tech/Engineering - Electronics / Elect Eng / Electricity
Spanish term or phrase: sala eléctrica de celdas
I am translating about power supply of an Hydraulic Plant.

Context: "Línea subterránea 13,8kV de conexión con la Subestación 110kV/13,8kV y Sala Eléctrica de celdas..."

Possible translation: Cell electrical room


I appreaciate your help.
Lauratje
Peru


Summary of answers provided
5Electrical room with cells (of ....) /cells of elecrical room
Graciela Silvia Parma
5room or control room (of substation)
cranesfreak
4electrochemical cell
Antonella Perazzoni
3electrical shelter sub-station cells
Lisa Rosengard


  

Answers


33 mins   confidence: Answerer confidence 5/5
Electrical room with cells (of ....) /cells of elecrical room


Explanation:
Las celdas transmiten la energía, son de diferentes tensiones, las salas entiendo son subestaciones, que sigue en el texto (no indica voltaje de media tensión o algo así?)

SALAS ELECTRICAS
Campos de Aplicación
Las Salas Eléctricas (Electrical Shelters) se emplean como sub-estaciones transportables para distribuir la energía eléctrica en Media Tensión y Baja Tensión; en lugares donde no es conveniente instalar sub-estaciones de obra civil como por ejemplo en Minas de Tajo abierto, Refinerías, Instalaciones con ambientes con alto contenido de contaminación ambiental, etc
Las Salas Eléctricas (Electrical Shelters) se construyen completamente equipadas en fábrica, preparadas para instalarlas sobre columnas de concreto o bases de concreto, facilitando una rápida puesta en servicio.
Su construcción se efectúa cumpliendo las normas ANSI/NEMA/IEEE.
Características Constructivas
Base de perfiles y canales de fierro estructural, cubierto con planchas de fierro de alta resistencia para posibilitar el desplazamiento de cargas pesadas en el interior de la Sala Eléctrica. El piso queda preparado para el anclaje de Celdas de Media Tensión y Tableros de Baja Tensión y cualquier otro equipamiento necesario; así como también permite el paso de los cables de fuerza y control hacia el exterior de la Sala Eléctrica.
La base también incluye orejas de fierro para permitir el izamiento con grúas de alta capacidad de carga.

Las paredes y techo disponen de aislamiento térmico y acústico y están construidas con planchas de fierro con dobleces para resistir los altos esfuerzos producidos durante el transporte, instalación y operación.

En los casos donde se requieran Salas Eléctricas muy grandes, éstas se construyen en varias secciones a fin de permitir su transporte terrestre o marítimo.
El equipamiento típico considerado en la mayoría de las Salas Eléctricas son:

Celdas de Media Tensión
Tableros de fuerza de Baja Tensión
Bancos de Baterías y Rectificador-Cargador
Tableros de Control, PLCs, Computadoras de Sistemas SCADA
Transformadores de distribución
Sistema de Iluminación interior
Sistemas de Iluminación exterior
Sistemas de alarma y/o extinción de fuego y humo
Canaletas, Tuberías conduit y cableado de fuerza y control
Sistema de aire acondicionado con o sin presión positiva
Equipos de protección personal y de maniobras
Otros requeridos por el cliente

Las puertas disponen de cerraduras antipánico, cerraduras y bisagras para trabajo pesado, empaquetaduras, sistema de cierre automático, empaquetaduras, aislamiento térmico y acústico.
Todas las partes metálicas disponen de conexión a tierra y la base de la sala eléctrica dispone de varios puntos para su conexión al sistema de puesta a tierra exterior.


    Reference: http://promelsa.com.pe
Graciela Silvia Parma
Works in field
Native speaker of: Native in SpanishSpanish
Notes to answerer
Asker: Muchas gracias, Silvia. Según el texto línea más abajo dice: "... la alimentación a la sala eléctrica (de la estructura de toma de agua) debe ser de 13.8 kV..."

Login to enter a peer comment (or grade)

3 hrs   confidence: Answerer confidence 5/5
room or control room (of substation)


Explanation:
One option for this context

What is control room in substation?
The relays, protection and control panels are installed in the controlled room. These panels along with PC aids in automatic operation of various circuit breakers, tap changers, autoreclosers, sectionalizing switches and other devices during faults and abnormal conditions.May 17, 2013

Requirements and Function of Substation Automation

HTH

Regards

--------------------------------------------------
Note added at 3 hrs (2020-08-15 21:18:14 GMT)
--------------------------------------------------

https://electrical-engineering-portal.com/requirements-and-f...

cranesfreak
Local time: 03:20
Specializes in field
Native speaker of: Native in SpanishSpanish
PRO pts in category: 132
Login to enter a peer comment (or grade)

1 day 23 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
electrochemical cell


Explanation:
Adjunto link de Schematic Arrangement of a Hydro Electric Power Plant como referencia

Example sentence(s):
  • ere are a lot of parameters for electronic and ionic conductor for PKL electrochemical cell.

    https://www.researchgate.net/figure/Schematic-Arrangement-of-a-Hydro-Electric-Power-Plant_fig1_308887222
Antonella Perazzoni
Argentina
Local time: 03:20
Native speaker of: Native in SpanishSpanish
Login to enter a peer comment (or grade)

2 days 3 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5
electrical shelter sub-station cells


Explanation:
An underground connection line to an electrical cell sub-station shelter is mentioned in the notes.

Example sentence(s):
  • Las salas eléctricas se emplean como sub-estaciones transportables para distribuir la energía eléctrica en Media Tensión y Baja Tensión en lugares donde no es conveniente instalar sub-estaciones de obra civil como refinerías, instalaciones
  • The electrical shelters are used as transportable sub-stations to distribute medium and low tension electrical energy where civil engineering sub-station installation work is not suitable, such as refineries and other installation plants, factories ..

    Reference: http://promelsa.com.pe/salas-electricas.htm
Lisa Rosengard
United Kingdom
Local time: 06:20
Native speaker of: English
PRO pts in category: 3
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search