(For pumps using jackscrews for motor go to step f).
Mount the magnetic base on the drive half coupling (a band clamp may be necessary to hold base due to limited space).
Position the tip of the indicator on the pump shaft just above the seal.
Slowly rotate the driver shaft.
Note and record the T.I.R. reading.
If this reading is more than 0.05 mm (0.002 in) unbolt the drive and reposition the driver in the direction required to reduce the T.I.R. to within the allowable limits
If a register fit is used for alignment, driver will be able to be moved only a few thousandths of an inch.
If enough movement is not obtainable then the male register can be filed to obtain acceptable T.I.R. readings.
On pumps using jackscrews for motor alignment, mount the dial indicator base on the O.D. of the motor half coupling.
Set the indicator on the shaft, position the dial to zero being careful that the indicator is in direct line with one of the jackscrews.